What is flue Draught

The difference between atmospheric pressure and the pressure existing in the furnace or flue gas passage of a boiler is termed as draft. Draft can also be referred to as the difference in pressure in the combustion chamber area which results in the motion of the flue gases and the air flow.

What is a flue draft?

This movement of combustion air and exhaust is called draft. In essence, it is the difference in pressure between the air/gasses inside the chimney flue and the outside air that creates this movement. Warmer, lighter gasses in the flue tend to move upward.

What is meant by boiler Draught?

DEFINITION  Boiler draught may be defined as the small difference between the pressure of outside air and that of gases within a furnace or chimney at the grate level, which causes flow of air/hot flue gases to take place through boiler.

What is Draught in chimney?

Draught is the pressure difference which causes a flow of air or gases from one point to another point in the boiler system. … To remove flue gases from the system after combustion and the heat exchange.

What is a natural Draught flue?

An effective natural draught (or atmospheric) flue will rapidly establish draught conditions that allow safe elimination of products of combustion, and avoid excessive spillage of products of combustion into living spaces.

What is Draught and types?

Draught is defined as the difference between absolute gas pressure at any point in a gas flow passage and the ambient (same elevation) atmospheric pressure.

How do you test a flue Draught?

  1. Visually inspect the draught gauge for signs of damage and/or defect.
  2. Ignite a small amount of fuel in the appliance and leave to burn for 20 minutes.
  3. Adjust pointer to zero (before each measurement).
  4. Position the gauge on a level base or hang upright.

What are the limitations of chimney Draught?

1. The maximum pressure available for producing natural draught by chimney is hardly 10 to 20 mm of water under the normal atmospheric and flue gas temperatures. Limitations 3. As there is no through mixing of air and fuel in the combustion chamber due to low velocity of air therefore combustion is very poor.

What is Draught in mechanical?

Mechanical or Fan Draught. Boiler draught is defined as the difference between absolute gas pressure at any point in a flow passage and the ambient (same elevation) atmospheric pressure. Draught is achieved a small pressure difference which causes the flow of air or gas to take place.

What is boiler Draught or draft?

The difference between atmospheric pressure and the pressure existing in the furnace or flue gas passage of a boiler is termed as draft. Draft can also be referred to as the difference in pressure in the combustion chamber area which results in the motion of the flue gases and the air flow.

Article first time published on

Why is boiler Draught necessary?

The draught is necessary to force air through the fuel bed/ grate to aid in proper combustion of fuel and to remove the products of combustion i.e. flue gases to the atmosphere after they have given their heat to water being evaporated in the boiler.

How are Draughts classified?

ADVERTISEMENTS: Classification of Boiler Draught: Natural, Artificial, Steam Jet and Mechanical. Draught may be defined as the small pressure difference which causes a flow of gas to take place. … Proper combustion in a boiler furnace can only occur when sufficient quantity of air is supplied to the burning fuel.

What are the three main types of flue?

There are three types of flu viruses: A, B, and C. Type A and B cause the annual influenza epidemics that have up to 20% of the population sniffling, aching, coughing, and running high fevers.

Is a flue a chimney?

A flue is simply a passage for conveying exhaust gases from an appliance to the outdoors. A flue may be a duct, pipe, vent, or chimney. An unlined chimney is technically a flue, even though an unlined chimney is a fire hazard.

How does a flue pipe work?

The purpose of the flue pipe is to remove harmful byproducts of the combusted, or burned, fuel from inside your home. If the byproducts are not properly ventilated from inside the home, then you can have a dangerous buildup of carbon monoxide.

How can I improve my chimney draft?

  1. Start with a Hot, Fast Fire. Starting a cold wood stove with a hot, fast fire will get the draft going the quickest. …
  2. Burn Extremely Low Moisture Wood. …
  3. Improve Airflow Around the Fire. …
  4. Warm the Chimney Flue. …
  5. Provide Enough Air to Replace the Air That is Lost.

How do you conduct a spillage test?

Open the appliance door and with a smoke match/pen (15 sec burn time) pass over the top and side edge of the opening of the combustion chamber, observe and record if the smoke/combustion products are drawn into the chimney or spill back into the room. Once the smoke is extinguished, close the appliance door.

What device measures draft?

Draft intensity is measured in “inches of water”. Just as a mercury barometer is used to measure atmospheric pressure in inches of mercury, a draft gauge is used to measure draft intensity (pressure) in inches of water.

What is overfire draft?

[¦ō·vər¦fīr ′draft] (mechanical engineering) The air pressure in a boiler furnace during occurrence of the main flame.

What is Draught in Applied Thermodynamics?

ADVERTISEMENTS: Draught is the pressure difference which is necessary to draw the required quantity of air for combustion and to remove the flue gases out of the system.

What is the physical basis of Natural draught produced by a chimney?

Explanation: Natural draught depends on density of gases in chimney and its height.

How artificial Draught is produced?

Induced Draught Here, an air fan is attached to the base of the chimney or nearer to it. When the fan rotates, it sucks the flue gases from the boiler furnace system. The suction of flue gases from the furnace producers a pressure difference between the outside air and inside flue gases, and which creates a draught.

What is chimney efficiency?

Efficiency of Chimney It may be Defined as the ratio of the energy required to produce the artificial draught (expressed in meters head or J/Kg of flue gas) to the mechanical equivalent of extra heat carried away per kg of flue gases due to the natural draught.

What is purpose of Draught?

What are the purpose of Draught? To supply required amount of air to the furnace for the combustion of fuel. The amount of fuel can be burnt per square foot of grate depends upon the quantity of air circulated through fuel bed. To remove the gaseous products of combustion.

Why we prefer artificial Draught in modern boilers?

Forced draught fan require less power because it has to handle cold and dense air, the volume per unit mass of which is less. Flow of flue gases through boiler is more uniform. … Due to above reason, there is no danger of fire to come out from boiler flue passage in case of a leakage. Hence Induced draught is more safe.

Is it flue or flu?

While these words sound the same, they have very different meanings: Flu is a noun and refers to an infectious viral disease. Flue is a noun and usually refers to a pipe or chimney for smoke or gases.

What opened flue appliances?

Open-flued appliances take their combustion air from the room or space in which they are installed and so contribute to the extract ventilation when in operation. They can also be arranged to provide adequate extract ventilation when not firing.

What is the difference between a flue and chimney?

A flue is the channel, pipe, or tube through which gases and smoke travel from a source of combustion (fireplace, furnace, boiler) to the outside environment. … A chimney is, on the other hand, in its simplest definition, the housing that encases the flue. It is usually made of masonry, brick, or stone.