5 Common Faults of a Glow-worm Boiler and How to Fix Them About Glow-worm boilers 1. Fault code F16 (Ci models) 2. Fault code F9 3. Fault codes F1, F3 & F4 (Flexicom CX range) 4. Fault code F14 (Flexicom CX range) 5. Fault codes F61, 62, 63, 64, 65, 67 (Betacom) Conclusion

What does fault code F16 mean on glow worm?

1. Fault code F16 (Ci models) If the code F16 flashes up on your Glow-worm Ci model, this indicates a flame detection fault with your boiler. It could very well be that the boiler itself requires a service, and the probe needs cleaned or replaced.

What does F9 mean on a glow worm boiler?

Fault code F9 Next is the dreaded F9 code. The main problem here is that it’s a very generic code which can point to a few different faults relating to pressure, circulation and diverter valve issues. First, check your pump is running, then check all electrics from the circuit board. Is the boiler going through the correct sequence?

Is there a model number for the glow worm?

It’s belongs to a close friend of mine which is why it took a little while to get the information. He tells me it’s a ” Glow Worm Compact Electronic”. No model number though. The way he described the problem it doesn’t sound as though it’s just a delay in the water coming through the pipes from the boiler.

What are the problems with the glow worm boiler?

Top 6 Glow-worm Boiler Problems Glow-worm Boiler Problems Glow-worm Error / Fault Code Low water pressure 108 or F22 Flame detection fault F16 No heating or hot water 501 Frozen condensate pipe F1, F4, F28 or F29

1. Fault code F16 (Ci models) If the code F16 flashes up on your Glow-worm Ci model, this indicates a flame detection fault with your boiler. It could very well be that the boiler itself requires a service, and the probe needs cleaned or replaced.

Fault code F9 Next is the dreaded F9 code. The main problem here is that it’s a very generic code which can point to a few different faults relating to pressure, circulation and diverter valve issues. First, check your pump is running, then check all electrics from the circuit board. Is the boiler going through the correct sequence?

What is the fault code on a flexicom glow worm boiler?

Fault code F14 (Flexicom CX range) If you were to look at the service manual, you’d find this fault states there’s a defective gas valve. However, check there is power from the PCB to the gas valve. If not, it’s not the gas valve at all, but either the PCB or the wiring harness.

Is the glow worm flexicom 18SX heating controller working?

Hi We have a Glow Worm Flexicom 18sx. It currently wont turn off heating and will not respond to the remote controller (Drayton, electric mounted … read more my boiler is flashing f 9 and when i press the recessed button it does not fix the problem. It is only two years old. I have a Glow worm Flexicom 18sx. … read more

What does F9 mean on glow worm flexicom?

Customer: Hi my name is ***** ***** Wylie, I have a flexicom 24cx glowworm boiler that doesn’t start up, it gives a F9 error, even after resetting. I … read more I have a glow worm flexicom cx 24. About a month ago my Hi I have a glow worm flexicom cx 24. About a month ago my boiler cut out and initially flashed f14.

What does F4 mean on a glow worm boiler?

Codes F1 and F4 indicate an ignition fault, however F3 is a fan speed fault. However, if the fan does not come up to speed, you have an ignition fault, anyway. I’d recommend getting a multimeter out and checking your readings from the PCB to the fan. Also, check ignition leads and power from the PCB.

Is the glow worm boiler part of Vaillant?

Glow-worm is part of the Vaillant Group, and the company has its own dedicated service engineers to cover both Glow-worm and Vaillant boilers. Parts are easily available and reasonably priced, and they are a popular option for many of my clients.

Where can I find a glow worm installer?

Choose the most convenient option to let us know how we can help. If you need to replace your existing Glow-worm boiler, here’s everything you need to know. See the Glow-worm installers in your local area. Everything you need to get your boiler back up and running as quickly as possible.

Is there a hot water heater with glow worm?

Offering unrivalled comfort with a continuous hot water supply and the perfect temperature in large households. You can’t see it, but you can feel it. Glow-worm delivers hot water as long as you want it.

How long does glow worm boiler last in UK?

Delivering instant hot water with easy to use controls. 7-year guarantees supported 7 days a week. Contact our UK Service team for help. Which Glow-worm boiler works for you and your home? Choose our convenient solutions for smaller households to benefit from hot water on demand and a perfectly heated home.

Is the British Gas 330 boiler a glow worm?

HI I HAVE A BRITISH GAS 330 CONDENSING BOILER FITTED IN 2005, WHICH I BELIEVE IS A GLOW WORM BOILER? IT HAS NOT BEEN SERVICED FOR 4 YEARS!*!*. IT WILL HEAT WATER ON ITS OWN OK BUT WHEN PUT ON TO HEATI … read more British Gas 330 is not working with error code F5.

What does fault F5 indicate on a British Gas 330 Glowworm?

I have a 330+ British Gas boiler showing fault f1. This is I have a 330+ British Gas boiler showing fault f1. This is because I switched on the system coming back from holiday, forgetting that the gas main was off. Gas is now on but how do I reset boiler to w … read more

Which is the British Gas 330 + boiler?

Is the British Gas 330+ boiler that I have a re-badged GlowWorm Flexicom HX or a re-badged GlowWorm Ultracom Sxi? There are conflicting thoughts on the forum. I’d like to get a plumber to change my hot water from vented to unvented and one boiler looks suitable and the other doesn’t.

Is the BG 330 + a Flexi or Glowworm?

The BG 330+ is not simply re-badged. It is a different from both the flexi and ultra. It is probably better described as a hybrid?? See no reason why a 330+ should prevent fitting an unvented cylinder. GlowWorm got back to me with the following reply.

What does it mean when your boiler is not igniting?

It could very well be that the boiler itself requires a service, and the probe needs cleaned or replaced. Please note though, I’ve also seen this code when the boiler is not igniting due to no gas coming through the pilot assembly, The Fix: Check the pilot assembly is clean and free flowing from the gas valve.

What happens if the boiler pressure is too low?

Boiler pressure is a term used to describe the pressure of the hot water running through the central heating system. Should the boiler pressure drop too low, the central heating will fail to work. Increasing the boiler pressure is something you can do without calling out a heating engineer.

How to contact British Gas 330 + boiler service?

British Gas 330+ British Gas Service Tel: 0845 9500400 2 These instructions consist of, Installation, Servicing, Fault Finding, Replacement of Parts and Spares. The instructions are an integral part of the appliance and must, to comply with the current issue of the Gas Safety (Installation and Use) Regulations, be handed to

What are the regulations for a British Gas Boiler?

In GB,the installation of the boiler must comply with the requirements of the current issue of BS6798 and be carried out by a competent person as described in the following regulations: The manufacturer’s instructions supplied. The Gas Safety (Installation and Use) Regulations.

Why is my Glow worm boiler not igniting?

Please note though, I’ve also seen this code when the boiler is not igniting due to no gas coming through the pilot assembly, The Fix: Check the pilot assembly is clean and free flowing from the gas valve. If so, replace the flame detection probe and lead.

You Might Also Like