Is the Potterton Suprima boiler in a cupboard?
The boiler we saw was in a garage, not enclosed in a cupboard. It clearly still had the old style circuit board, in fact one of the earliest circuit boards fitted to the Potterton Suprima, with a membrane panel which has to be pressed to re-set the boiler if it locks out.
Where can I find Potterton Suprima noisy fan advice?
Discuss Potterton Suprima noisy fan advice please in the Central Heating Forum area at PlumbersForums.net Not open for further replies.
What does flashing red mean on Potterton Suprima boiler?
I can’t remember now.) The Potterton Suprima Replacement PCB Kit manual says that flashing red 3 times/sec indicates an air pressure switch (APS) fault or a flow switch fault. We opened the boiler up to check if a flow switch was fitted (sometimes called a dry fire switch) but there was none on this boiler.
When did the Potterton Suprima circuit board come out?
The data plate carried a “00” year code indicating it was manufactured in 2000. We removed the screw which allows the control panel to flip down and inspected the board, finding the classical darkened scorch mark which is typical of Potterton Suprima circuit boards of this type.
Where to cut spring support on Potterton flue?
It is recommended that tape is used as a guide to first cut around the air duct and then the exhaust duct be cut square and flush with the air duct. The spring support should be positioned approximately 100mm from the male end of the extension to maintain concentricity.
When does the Potterton Suprima 50l boiler reach temperature?
The problem shows itself up when the central heating is on. The boiler starts its sequence: fan on, gas lights and burns for 5 seconds then boiler stops with a flashing green light which means the boiler thinks it is up to temperature. I have changed the thermister but the problem is still there.
Are there any problems with the Potterton Suprima?
They came in many heat output sizes from 30,000 BTUs right up to 120000 BTUs and all in the same size case. The 120s were recalled a few times due to problems and eventually withdrawn, but all in all, they were a good boiler. The Potterton suprima had its faults though and one of them was the PCB or otherwise known as the printed circuit board.
Are there any problems with the Potterton 120?
The 120s were recalled a few times due to problems and eventually withdrawn, but all in all, they were a good boiler. The Potterton suprima had its faults though and one of them was the PCB or otherwise known as the printed circuit board.
What should hot water temp be in Potterton?
Pull the door panel open. Confirm Status LED shows continuous Orange. Turn the temperature control knob to adjust the radiator temperature between approximately 55°C and 82°C. Hot water temperature is usually controlled by a thermostat on the hot water cylinder.