How do you reset a Vokera compact?
To reset the appliance, make sure the gas supply is on to the appliance. Turn the mode selector switch to the OFF position for a few seconds and then turn it back to its previous position. If the red LED stays on or is illuminated after a few seconds call an engineer.
Why is the red light flashing on my gas boiler?
Usually, when modern boilers need resetting they will display a fault code or begin to flash a red or green light. These signals indicate that your boiler senses a problem, which is why it has stopped working and needs to be reset.
Why is my boiler on lockout?
A boiler lockout is a shut-down procedure that is initiated when a boiler is not working within certain tolerances. This could be due to low/high water pressure, lack of or no fuel supply (gas, LPG or oil), a blockage in the system or lack of power to electronic components.
What does vokera compact fault code A03 mean?
Vokera Compact fault code A03 The Fault: The above fault code means there’s likely a fault with your boiler’s fan; it may have become worn down over time. The Fix: Test it out with a volt meter; if power levels are correct, it’s definitely time to replace your fan. If there’s no power, check the wiring from the PCB. 5.
Why does my vokera boiler keep locking out?
Heat exchanger blockage – if you hear any whistling noise coming from the boiler, then there is chance that there is lime scale build up on the heat exchanger which needs to be cleaned. These are some of the problems which may cause the boiler lockout.
What does vokera Linea fault code 40 / 41 mean?
Vokera Linea fault code 40/41 (Vokera Compact code A04) The Fault: The codes above mean your boiler’s pressure levels are low. Sometimes this can happen if there’s a leak, or if an air bubble has found its way into the system. The Fix: Locate the filling loop underneath your boiler and top up the pressure to 1 – 1.5 bar.
What does a code 10 on a vokera boiler mean?
Press the reset button and watch your boiler fire back to life. 2. Vokera Linea fault code 10 (Vokera Compact code A01) The Fault: The above codes mean that there is an ignition failure with your boiler, in which case you can probably hear your boiler sparking but failing to ignite.
Vokera Compact fault code A03 The Fault: The above fault code means there’s likely a fault with your boiler’s fan; it may have become worn down over time. The Fix: Test it out with a volt meter; if power levels are correct, it’s definitely time to replace your fan. If there’s no power, check the wiring from the PCB. 5.
Heat exchanger blockage – if you hear any whistling noise coming from the boiler, then there is chance that there is lime scale build up on the heat exchanger which needs to be cleaned. These are some of the problems which may cause the boiler lockout.
Vokera Linea fault code 40/41 (Vokera Compact code A04) The Fault: The codes above mean your boiler’s pressure levels are low. Sometimes this can happen if there’s a leak, or if an air bubble has found its way into the system. The Fix: Locate the filling loop underneath your boiler and top up the pressure to 1 – 1.5 bar.
Press the reset button and watch your boiler fire back to life. 2. Vokera Linea fault code 10 (Vokera Compact code A01) The Fault: The above codes mean that there is an ignition failure with your boiler, in which case you can probably hear your boiler sparking but failing to ignite.