How do you replace a thermal coupler on a gas fireplace

Procedure for Replacing a Thermocouple Turn off the gas supply to the gas valve. Use the wrench to unscrew the connector that holds the thermocouple to the gas valve, then unhook the probe from its clip and pull out the entire thermocouple assembly. Take the thermocouple to the hardware store to purchase a new one.

How do you change a thermocouple on a gas fireplace?

Procedure for Replacing a Thermocouple Turn off the gas supply to the gas valve. Use the wrench to unscrew the connector that holds the thermocouple to the gas valve, then unhook the probe from its clip and pull out the entire thermocouple assembly. Take the thermocouple to the hardware store to purchase a new one.

How do I know if my thermocouple is bad on my gas fireplace?

The Fix: Pilot Light to Gas Fireplace Won’t Stay Lit So you’ve checked your pilot light and even reset it, but still, it wont stay lit. This can be an indication that your fireplace thermocouple is either bad or worn out.

How do you know if you have a bad thermocouple?

If you can’t get the flame to light at all, and you’re sure the gas is on, there’s probably an obstruction in the pilot tube. If the flame lights and goes out when you release the gas control knob after holding it in for the recommended 20 to 30 seconds, that’s the sign of a thermocouple malfunction.

Where is the thermocouple located on a gas fireplace?

Find the thermocouple, which is located next to the pilot light and looks like a small straight pipe.

How much does it cost to replace thermocouple?

It costs $150 to $250 to replace a thermocouple. It checks to make sure the pilot light is on. It will shut the gas off if it’s not.

Can I replace a thermocouple myself?

1 cause of pilot lights that won’t stay lit is a worn-out thermocouple. It’s easy to replace and a new one costs $5 to $10. … Then detach the thermocouple from the burner and take it with you to the home center or hardware store to ensure you buy the right replacement.

What causes a thermocouple to go bad?

The presence of oxygen causes a reaction in the thermocouple that can wear down the part and make the wires become thinner and more brittle. Oxidation can be caused by a small amount of oxygen making its way into a sealed environment and reacting with the pure metal of the thermocouple.

How long does a thermocouple last on a gas fireplace?

The thermocouple usually lasts for ten years. However, if it malfunctions, the pilot will not light, and the fireplace will not operate. As a result, a thermocouple is a crucial component in the operation of a fireplace. If it quits running, the fireplace will also cease working.

Can you clean a thermocouple?

Yes, you can clean a thermocouple, but the task must be done with a light touch. Remove the thermocouple from the process assembly, using a steel wool or emery cloth, lightly clean the tip removing any build up.

Article first time published on

Will a pilot light stay lit with a bad thermocouple?

A thermocouple senses the heat of the pilot and allows gas to flow to the burner. A bad thermocouple will shut off gas to both the pilot and the burner so the pilot light won’t stay lit.

What's a thermocouple look like?

What does a thermocouple look like and how do you find it? … The thermocouple is made up of a tube, a bracket, and wires. The tube sits above the bracket, a nut holds the bracket and wires in place, and underneath the bracket, you will see the copper lead wires that connect to the gas valve on the furnace.

Why won't my pilot light stay lit on my gas fireplace?

If the pilot light on your gas fireplace won’t stay lit, a very likely culprit is a component called a thermocouple. A thermocouple is a safety device and is a component of the ignition system. … The thermocouple is a metal rod that sticks out right in front of the pilot itself. It senses if flame is present or not.

What happens if a thermocouple fails?

If the appliance has a thermocouple, the problem may be a faulty thermocouple. The thermocouple, which operates as a safety device, turns the gas supply off when the pilot light goes out. … When a thermocouple fails, the pilot light won’t stay lighted. A burned out or broken thermocouple should be replaced.

What tools do I need to change a thermocouple?

Use an adjustable wrench as needed to remove thermocouple from the gas valve. Detach the thermocouple from the pilot assembly. Some thermocouples can be pulled free, while others require screws to be detached with a screwdriver first.

How do I know which thermocouple to buy?

You want to get one that is about the same length as the one you have. They are sold in in 6″ increments for the shorter lengths, 18″, 24″, 30″ and so on. For a water heater, 18″ and 24″ are common, although longer ones are possible. Remove the old thermocouple and measure it to see what length you need.

Are thermocouples universal?

Honeywell, White Rodgers, and other manufacturers make universal replacement thermocouples, usually with a 30-millivolts (mV) rating for standing-pilot furnaces. … Electronic flame sensors are much less universal, and you must find the exact part specified for your furnace model.

What is a thermocouple and what does it do?

Thermocouples are sensors used to measure temperature. … A thermocouple consists of two wires, or wire legs, made from different metals. The legs are welded together at one end, into a junction, where the temperature is measured. A voltage is created when the junction senses a change in temperature.

Why does my gas heater keep cutting out?

If your furnace keeps shutting off, it could be due to low airflow. There are several indirect issues that cause low airflow. Dirty Air Filters. If you don’t change your air filters often enough, the filters will become dirty and clogged, which means the heat exchanger retains heat and eventually causes it to overheat.

Should thermocouple be in pilot flame?

The pilot flame should touch the thermocouple at a specific level. If the flame is blue and weak, and barely reaches the thermocouple, it needs to be stronger. If it extends well above the thermocouple, it’s too strong. … Install a new thermocouple by screwing it in, heating it up a bit, and then lighting the pilot.

Why does my gas fireplace keep going off and on?

A thermo pile enables gas to move through the burner system, delivering the gas fireplace’s heat and light. … One of these devices could have gone bad or may have shorted out, causing your fireplace to turn shut down or turn back on at random.

How do you bypass a thermocouple?

  1. Move the tilts switch wire aside.
  2. Remove your thermocouple from the heater using an 8mm wrench.
  3. Pull the valve housing aside using your 13mm socket wrench. …
  4. Remove the valve using your pliers. …
  5. Put your thermocouple back into position.

How do you clean a dirty thermocouple?

The best way to clean your thermocouple is to use either a piece of steel wool or the coarse side of a sponge to gently clean off any soot or other remnants. You can use a pencil eraser to clean between the threads of the screw that connects the thermocouple to the control valve of your system.

Is a flame sensor and thermocouple the same thing?

People tend to use the terms “flame sensor” and “thermocouple” interchangeably. In truth, while they basically perform the same job, they’re not the same thing. If your furnace uses an electronic controller, it’s got a flame sensor. Thermocouples are used on standing pilot furnaces that have pilot lights.

How do I stop the wind from blowing out my pilot light?

You can prevent a faulty pilot light from wind by fixing your thermocouple, gas release, protecting against downdrafts, capping your chimney, and checking your firebox cover.