How do I reset my Potterton Suprima?
Press the reset button for 10 seconds, the LED will flash Orange once then return to normal operation.
Are Potterton boilers good?
If you’ve read any of our other boiler reviews, you’ll know we recommend a 5 year warranty as a minimum for your boiler system. So, considering Potterton is comparable in terms of reliability and quality, the boiler prices are good. They’re are premium boilers, but at the lower end of premium.
What does amber light on Potterton boiler mean?
Looking at the fault finding guide which comes with the PCB upgrade kit, a flashing orange light on the PCB indicates that there is a problem with the temperature control and suggests to check the temperature control on the boiler is switched up which it was. …
What is the lifespan of a Potterton boiler?
Servicing older Potterton boilers is usually easy peasy, but you may find you need to spend money on repairs. However, it’s worth remembering that even the best brands having a life span of around 14 – 16 years.
Is the Potterton Suprima boiler in a cupboard?
The boiler we saw was in a garage, not enclosed in a cupboard. It clearly still had the old style circuit board, in fact one of the earliest circuit boards fitted to the Potterton Suprima, with a membrane panel which has to be pressed to re-set the boiler if it locks out.
When did the Potterton Suprima circuit board come out?
The data plate carried a “00” year code indicating it was manufactured in 2000. We removed the screw which allows the control panel to flip down and inspected the board, finding the classical darkened scorch mark which is typical of Potterton Suprima circuit boards of this type.
What does flashing red mean on Potterton Suprima boiler?
I can’t remember now.) The Potterton Suprima Replacement PCB Kit manual says that flashing red 3 times/sec indicates an air pressure switch (APS) fault or a flow switch fault. We opened the boiler up to check if a flow switch was fitted (sometimes called a dry fire switch) but there was none on this boiler.
How can I Fix my Potterton prima’f’boiler?
Navigate to How can I fix my Potterton Prima ‘F’ boiler? When the hot water or heating is switched on the boiler attempts to start up, i.e. the fan starts and stays on for about 15 seconds and then stops for about 10 seconds. This cycle goes on for about 10 attempts before the boiler finally lights up. Then it behaves normally, well almost!
Are there any problems with the Potterton Suprima?
They came in many heat output sizes from 30,000 BTUs right up to 120000 BTUs and all in the same size case. The 120s were recalled a few times due to problems and eventually withdrawn, but all in all, they were a good boiler. The Potterton suprima had its faults though and one of them was the PCB or otherwise known as the printed circuit board.
When does the Potterton Suprima 50l boiler reach temperature?
The problem shows itself up when the central heating is on. The boiler starts its sequence: fan on, gas lights and burns for 5 seconds then boiler stops with a flashing green light which means the boiler thinks it is up to temperature. I have changed the thermister but the problem is still there.
Are there any problems with the Potterton 120?
The 120s were recalled a few times due to problems and eventually withdrawn, but all in all, they were a good boiler. The Potterton suprima had its faults though and one of them was the PCB or otherwise known as the printed circuit board.
The data plate carried a “00” year code indicating it was manufactured in 2000. We removed the screw which allows the control panel to flip down and inspected the board, finding the classical darkened scorch mark which is typical of Potterton Suprima circuit boards of this type.