1 Manual reset is accomplished by first, turning off power to the water heater for 10 seconds. 2 Restore the power to the water heater. 3 Within 10 seconds of restoring power, press the two temperature adjust buttons simultaneously until the left (green) “Vacation” LED begins to blink (approx. 5 second delay).

What gas valve does AO Smith use?

Smith by Honeywell Gas Control Valve 100262939 2″ Cavity Natural Thermostat Compatible with A.O. Smith, State, American, Whirlpool, and Craftmaster Brand Water Heaters.

How to use Intelli vent control on water heater?

sensed by the Intelli-Vent™ control. 1 Ensure the wall outlet is properly grounded. 2 Ensure all ground connections/wires on the water heater are secure. 2 Power supply to Intelli-Vent™ control has reversed polarity. 1 Ensure the wall outlet is properly wired. 2 Ensure all internal 120 VAC wiring connections and

Where can I get an O Smith Intelli-vent troubleshooting manual?

Page 28 Additional copies are available from the Ashland City Advertising Department Prepared by the A. O. Smith/State Water Heater Technical Training Department Ashland City, Tennessee…

How to troubleshoot an intelli-vent hot surface ignitor?

Page 13 • Check all wiring to the hot surface ignitor. • Check 5 pin Molex ignitor assembly plug and receptacle on the Intelli-Vent™ body for a good connection. Repair or replace parts if necessary. • Check resistance of ignitor with an ohm meter between pin 1 and 2 on the ignitor assembly plug.

When to replace the Intelli-vent ignitor assembly?

A If the reading taken is more than 50,000 ohms replace the ignitor assembly. B If the reading taken is less than 50,000 ohms replace the Intelli-Vent™ control. Technical Training Department Ashland City, Tennessee ©…

Page 28 Additional copies are available from the Ashland City Advertising Department Prepared by the A. O. Smith/State Water Heater Technical Training Department Ashland City, Tennessee…

Page 13 • Check all wiring to the hot surface ignitor. • Check 5 pin Molex ignitor assembly plug and receptacle on the Intelli-Vent™ body for a good connection. Repair or replace parts if necessary. • Check resistance of ignitor with an ohm meter between pin 1 and 2 on the ignitor assembly plug.

How do you turn an Emerson Intelli vent?

1. Apply pipe compound to the male threads of the pipe that goes into the control, leaving the first two or three threads clean. 2. Install control in the tank. Turn clockwise ( ). Use a short piece of pipe to help in turning. Align the control so that the burner tube may be connected. 3. Make the main burner connection.